Home/News/Four Mistakes in Using Pipettes

Four Mistakes in Using Pipettes

Jul 07, 2022
The first mistake: When the pipette tip contains liquid, it is placed on the table.
Correction: Hang the pipette tip vertically on the pipette tip holder.
Analyses: The pipette tip contains liquid. After the pipette tip is placed on the table, the liquid may flow into the pipette tip body, which will affect the internal components of the pipette tip, and may cause serious damage and cross-contamination.
 
The second mistake: Use a large-capacity pipette tip to obtain liquids with small volumes.
Correction: The pipetting volume must be within the range provided by the pipette tip to meet the requirements of accuracy and precision.
Analyses: The existence of the air cushion is the main reason for the inaccuracy of the pipettor. The selection of the pipettor should be based on the selection principle of the maximum range and the liquid transfer volume closest to the target.
 
The third mistake: Absorb liquids with good volatility.
Correction: It is not recommended to use ordinary pipettors for transferring liquids with good volatility.
Analyses: If it is necessary to transfer a liquid with good volatility, the pipettor should be disassembled immediately after pipetting to allow the vapor to evaporate. At the same time, it is recommended to use an external piston pipettor.
 
The fourth mistake: The suction speed and discharge speed are too fast.
Correction: the liquid should be sucked and released slowly.
Analyses: For pipette tips with a volume of 1mL and above, it is easy to cause liquid to go upward. Discharging too quickly will increase the residual volume of the liquid.
 


Previous: Pipettes
Next: CACLP Experimental Medicine, in Vitro Diagnostic Feast

Name*
E-mail*
Rate*
Comments*

About the author
Teresa
Teresa
pu*****************om
Teresa is a skilled author specializing in industrial technical articles with over eight years of experience. She has a deep understanding of manufacturing processes, material science, and technological advancements. Her work includes detailed analyses, process optimization techniques, and quality control methods that aim to enhance production efficiency and product quality across various industries. Teresa's articles are well-researched, clear, and informative, making complex industrial concepts accessible to professionals and stakeholders.

Latest News

Different Types of Laboratory Tubes and Their Uses

Different Types of Laboratory Tubes and Their Uses

September 3, 2024
News Detail
Purpose and Precautions of Magnetic Rod Sleeve

Purpose and Precautions of Magnetic Rod Sleeve

August 27, 2024
News Detail
Considerations for Precision Automated Pipetting

Considerations for Precision Automated Pipetting

August 21, 2024
News Detail
China Pipette Tip Manufacturer
Products
  • Universal Pipette Tips (112)
  • Automatic Pipette Tips (7)
  • PCR (38)
  • Centrifuge Tubes (27)
  • Deep Well Plates (23)
  • Magnetic Rod Sleeves (1)
  • Safety Goggles (1)
  • Robotic Tips (0)
Latest News
  • Different Types of Laboratory Tubes and Their Uses
  • Purpose and Precautions of Magnetic Rod Sleeve
  • Considerations for Precision Automated Pipetting
  • Why is Balancing Centrifuges Important?
Follow us
  • Twitter
  • Facebook
  • Youtube
  • Instagram
Resources
  • About Us
  • Contact Us
  • Products
  • Sitemap
  • Glossary
  • Tags
  • Privacy and Policy
  • Terms
© 2026 Chengdu Pulse Optics-tech Co., Ltd., All Rights Reserved.
Website Design & Support: jeawin.com
Links: Plastic Injection Molding, China Manufacturers.